{"id":905,"date":"2016-05-13T20:37:03","date_gmt":"2016-05-13T18:37:03","guid":{"rendered":"http:\/\/calorstone.com\/fr\/calcolo-rendimenti-termici-calorstone\/"},"modified":"2019-05-14T07:37:22","modified_gmt":"2019-05-14T05:37:22","slug":"calcolo-rendimenti-termici-calorstone","status":"publish","type":"post","link":"https:\/\/calorstone.com\/fr\/calcolo-rendimenti-termici-calorstone\/","title":{"rendered":"Calcul des rendements thermiques avec panneaux radiants calorstone"},"content":{"rendered":"<h2>Calcul rendements thermiques<\/h2>\n<p>Comme tous les syst\u00e8mes de\u00a0<strong><u>chauffage,<\/u><\/strong>\u00a0ceux qui exploitent les <strong><u>syst\u00e8mes radiants \u00e0 infrarouges<\/u><\/strong>\u00a0doivent \u00e9galement \u00eatre calcul\u00e9s par rapport aux caract\u00e9ristiques de la maison ou g\u00e9ographiques. Il faut particuli\u00e8rement tenir compte des\u00a0<strong>temp\u00e9ratures minimales externes du projet, le degr\u00e9s-jour et l\u2019isolation<\/strong>\u00a0de la maison qui d\u00e9terminent la puissance radiante \u00e0 installer.<\/p>\n<p>En conditions, pour ainsi dire, \u00a0<strong>peu favorables<\/strong>\u00a0(<strong>coefficient de transmission des parois au-del\u00e0 de 0.9 W\/mc \u00b0C<\/strong>) il pourrait \u00eatre n\u00e9cessaire d\u2019installer jusqu\u2019\u00e0\u00a0<strong>50 W\/mc<\/strong>\u00a0pour chaque pi\u00e8ce que l\u2019on veut \u00e9quiper de panneaux radiants. La n\u00e9cessit\u00e9 de puissance diminue aussi bien en fonction de l\u2019isolation de la maison qu\u2019en fonction de l\u2019\u00e9l\u00e9vation de la temp\u00e9rature minimale du projet et de la diminution de degr\u00e9-jour. Par exemple pour des maisons passives il est possible de descendre\u00a0<strong>jusqu\u2019\u00e0 12 W\/mc<\/strong>. Il est \u00e9vident que dans le cas de maisons passives les panneaux radiants infrarouges sont install\u00e9s afin d\u2019augmenter le confort et la sensation de chaleur sur la peau)<\/p>\n<p>Le calibrage d\u00e9pend aussi d\u2019autres facteurs tels que:<\/p>\n<p>1) l\u2019emploi de la maison (habituelle ou de vacances)<\/p>\n<p>2) si le syst\u00e8me radiant r\u00e9sulte \u00eatre int\u00e9gratif ou comme unique syst\u00e8me de chauffage.<\/p>\n<p>3) les habitudes personnelles<\/p>\n<p>Il est \u00e9galement important de pouvoir\u00a0<strong><u>pr\u00e9voir avec une grande certitude la consommation \u00e9lectrique<\/u><\/strong>\u00a0et le co\u00fbt annuel de fonctionnement. En effet, la puissance \u00e9lectrique install\u00e9e dans ce cas est en\u00a0<strong>rapport 1:1 (COP=1)<\/strong>\u00a0avec la puissance thermique n\u00e9cessaire pour chauffer une pi\u00e8ce.<\/p>\n<p>Faisons trois exemples de\u00a0<strong>consommation maximale<\/strong>.<\/p>\n<p><strong>1)<\/strong>\u00a0Si l\u2019on veut chauffer avec des panneaux radiants un local (chambre ) de \u00a0<strong>20 m2 ayant une hauteur de 2m7<\/strong>. Faisons \u00e9galement l\u2019hypoth\u00e8se que le local \u00e0 chauffer soit peu isol\u00e9 thermiquement (environ\u00a0<strong>0.8<\/strong>\u00a0<strong>W\/m2 \u00b0C)\u00a0<\/strong>et qu\u2019il faille\u00a0<strong><u>30 W\/mc de puissance thermique.<\/u><\/strong>.<\/p>\n<p>A ce point la puissance \u00e9lectrique \u00e0 installer est exactement<\/p>\n<p><strong>30 (W\/mc) x 20 (m2) x 2.7 (m) = \u00a01620 W<\/strong><\/p>\n<p>en supposant de garder continuellement allum\u00e9 (<strong>ce qui n\u2019arrive pratiquement jamais si l\u2019on installe un chrono-thermostat ou s\u2019il est d\u00e9j\u00e0 pr\u00e9sent dans le panneau<\/strong>) le panneau radiant pendant\u00a0<strong>5 heures<\/strong>\u00a0on consomme une quantit\u00e9 d\u2019\u00e9nergie \u00e9lectrique \u00e9gale \u00e0<\/p>\n<p><strong>1620 (W) x 5 (h) = 8100 Wh= 8.1 kWh<\/strong><\/p>\n<p>en imaginant de payer l\u2019\u00e9nergie \u00e9lectrique 0.22 \u20ac\/kWh on calcule le co\u00fbt journalier<\/p>\n<p><strong>8.1 (kWh) x 0.22 (\u20ac\/kWh) = 1.72 \u20ac\/jour.<\/strong><\/p>\n<p><strong>2)<\/strong>\u00a0Si l\u2019on consid\u00e8re la m\u00eame pi\u00e8ce (20 m2, 2.7 m de hauteur) mais avec une isolation thermique suffisante (environ 0.5 W\/m2 \u00b0C). Dans ce cas-l\u00e0 la puissance n\u00e9cessaire par m\u00e8tre cube \u00e0 installer est\u00a0<strong>22 W\/mc<\/strong>.<\/p>\n<p>la puissance totale sera donc:<\/p>\n<p><strong>22 (W\/mc) x 20 (m2) x 2.7 (m) = \u00a01188 W<\/strong><strong><br \/>\n<\/strong><\/p>\n<p>en supposant de garder continuellement allum\u00e9 (<strong>ce qui n\u2019arrive pratiquement jamais si l\u2019on installe un chrono-thermostat ou s\u2019il est d\u00e9j\u00e0 pr\u00e9sent dans le panneau<\/strong>) le panneau radiant pendant 5 heures\u00a0on consomme une quantit\u00e9 d\u2019\u00e9nergie \u00e9lectrique \u00e9gale \u00e0<\/p>\n<p><strong>1188 (W) x 5 (h) = 5940 Wh= 5.9 kWh<\/strong><\/p>\n<p>en imaginant de payer l\u2019\u00e9nergie \u00e9lectrique 0.22 \u20ac\/kWh on calcule le co\u00fbt journalier<\/p>\n<p><strong>5.9 (kWh) x 0.22 (\u20ac\/kWh) = 1.23 \u20ac\/jour.<\/strong><\/p>\n<p><strong>3) <\/strong>essayons maintenant de chauffer la m\u00eame pi\u00e8ce (20 m2, 2m7 m de hauteur) dans une maison passive, avec une excellente isolation thermique (environ 0.12 W\/m2 \u00b0C). Dans ce cas-l\u00e0 la puissance n\u00e9cessaire par m\u00e8tre cube \u00e0 installer est <strong>5 W<strong>\/mc<\/strong><\/strong>.<\/p>\n<p>la puissance totale sera donc:<\/p>\n<p><strong>5 (W\/mc) x 20 (m2) x 2.7 (m) = \u00a0270 W<\/strong><\/p>\n<p>en supposant de garder continuellement allum\u00e9 (<strong>ce qui n\u2019arrive pratiquement jamais si l\u2019on installe un chrono-thermostat ou s\u2019il est d\u00e9j\u00e0 pr\u00e9sent dans le panneau<\/strong>) ) le panneau radiant pendant 5 heures on consomme une quantit\u00e9 d\u2019\u00e9nergie \u00e9lectrique \u00e9gale \u00e0<\/p>\n<p><strong>270 (W) x 5 (h) = 1350 Wh= 1.3 kWh<\/strong><\/p>\n<p>en imaginant de payer l\u2019\u00e9nergie \u00e9lectrique 0.22 \u20ac\/kWh on calcule le co\u00fbt journalier<\/p>\n<p><strong>1.3 (kWh) x 0.22 (\u20ac\/kWh) = 0.28 \u20ac\/jour.<\/strong><\/p>\n<p><strong><u>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<\/u><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>NB: Dans tous les cas avec les panneaux radiants \u00e9lectriques \u00e0 \u00e9mission infrarouge il est toujours de bonne norme de sur-calibrer l\u00e9g\u00e8rement l\u2019installation radiante install\u00e9e. Etant donn\u00e9 qu\u2019il est possible de r\u00e9gler la temp\u00e9rature d\u2019exercice des panneaux radiants \u00e9lectriques C plus basse que celle des chauffages classiques, en sur-calibrant l\u00e9g\u00e8rement la puissance install\u00e9e, on obtient d\u2019importantes \u00e9conomies d\u2019\u00e9nergie \u00e9lectrique.<\/strong><\/p>\n<p>Bien s\u00fbr, si l\u2019on dispose d\u2019une\u00a0<strong><u>installation photovolta\u00efque<\/u><\/strong>, l\u2019\u00e9nergie est autoproduite et, aussi bien dans le cas o\u00f9 il est possible d\u2019acc\u00e9der \u00e0 l\u2019\u00e9change sur place que dans le cas d\u2019avantages fiscaux (ou tous les deux avec les vieux comptes \u00e9nergie) le\u00a0<strong><u>chauffage devient pratiquement \u00e0 co\u00fbt z\u00e9ro.<\/u><\/strong><\/p>\n<p>En r\u00e9alit\u00e9 l\u2019installation de panneaux radiants d\u00e9termine la possibilit\u00e9 de chauffer\u00a0<strong>non seulement la pi\u00e8ce, c\u2019est \u00e0 dire l\u2019air<\/strong>\u00a0mais aussi\u00a0<strong>la peau,\u00a0<\/strong>les objets, les murs, le sol.<strong>Avec ce syst\u00e8me de chauffage on per\u00e7oit le flux de chaleur incidente presque instantan\u00e9ment<\/strong>.<\/p>\n<p>Cela signifie qu\u2019un panneau radiant peut \u00eatre\u00a0<strong>allum\u00e9 quand et o\u00f9 il est n\u00e9cessaire<\/strong>. Les co\u00fbts d\u00e9rivant de la <strong>consommation \u00e9lectrique deviennent donc minimes m\u00eame pour les personnes qui n\u2019ont pas la possibilit\u00e9 de pr\u00e9voir une installation photovolta\u00efque. <\/strong>.<\/p>\n<p>De plus l\u2019installation de\u00a0<strong>centrales de gestion des charges \u00e9lectriques<\/strong>\u00a0peuvent<strong>\u00a0r\u00e9duire ult\u00e9rieurement les consommations sans devoir effectuer de changement de puissance \u00e9lectrique disponible pour l\u2019habitation <\/strong>\u00a0 (les fameux 3.3 kW, 6 kW, 10 kW ou plus fournis par les g\u00e9rants du r\u00e9seau).      <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Comme tous les syst\u00e8mes de chauffage, ceux qui exploitent les syst\u00e8mes radiants \u00e0 infrarouges doivent \u00e9galement \u00eatre calcul\u00e9s par rapport aux caract\u00e9ristiques de la maison ou g\u00e9ographiques.<\/p>\n<a class=\"readmore-button\" href=\"https:\/\/calorstone.com\/fr\/calcolo-rendimenti-termici-calorstone\/\">Read More<\/a>","protected":false},"author":7,"featured_media":562,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,31,32,5,1],"tags":[],"class_list":["post-905","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ab-cupidatat-philos","category-ab-cupidatat-philos-fr","category-o-irure-nostrud-non-fr","category-o-irure-nostrud-non","category-senza-categoria"],"_links":{"self":[{"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/posts\/905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/comments?post=905"}],"version-history":[{"count":0,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/posts\/905\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/media\/562"}],"wp:attachment":[{"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/media?parent=905"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/categories?post=905"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/calorstone.com\/fr\/wp-json\/wp\/v2\/tags?post=905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}