{"id":11580,"date":"2016-05-13T20:37:03","date_gmt":"2016-05-13T18:37:03","guid":{"rendered":"https:\/\/calorstone.com\/calcolo-rendimenti-termici-calorstone\/"},"modified":"2022-12-07T22:14:59","modified_gmt":"2022-12-07T21:14:59","slug":"calcolo-rendimenti-termici-calorstone","status":"publish","type":"post","link":"https:\/\/calorstone.com\/en\/calcolo-rendimenti-termici-calorstone\/","title":{"rendered":"Reckoning thermal yelds of Calorstone radiant panels"},"content":{"rendered":"<h2>Reckoning thermal yelds<\/h2>\n<p class=\"p1\">The <b>heating systems through radiant<\/b> panels must be sized according to the features of the house and to geographical conditions, so as all <b>heating systems<\/b>. Especially, we must consider <b>external minimum project temperatures<\/b>, <b>day-degrees and insulation of the house<\/b> to define radiant power to be installed.<\/p>\n<p class=\"p1\"><b>In unfavourable conditions (wall transmittancy over 0,9 W\/mq \u00b0C)<\/b>, it might be needed to install up to <b>50 W\/m3<\/b> per room. The needed power decreases thanks to the insulation of the house, to increasing of minimum project temperature, and to the decreasing of day-degrees. For instance, in passive houses we can go down to <b>12 W\/m3<\/b>. Definitely in passive houses we can install radiant panels to inhance comfort and the heat sensation on the skin.<\/p>\n<p class=\"p1\">The size of the system depends on more factors, such as:<\/p>\n<p class=\"p1\">1) use of the house (usual, for holidays)<\/p>\n<p class=\"p1\">2) if the system is the only heating system or it has to help a resident system<\/p>\n<p class=\"p1\">3) personal habits<\/p>\n<p class=\"p1\">Another important thing to consider is that we can quite surely <b>foresee the electric consumption<\/b> and the cost per year. Indeed, the installed power is in a <b>1:1 report (COP=1) <\/b>with thermal power needed to heat a room.<\/p>\n<p class=\"p1\">Let\u2019s see 2 practical instances of maximum consumption:<\/p>\n<p class=\"p1\"><b>1)<\/b> We need to heat a room with <b>20 sm area and 2.7 m height<\/b>; if we hypothesize the room is slightly insulated (<b>0,8 W\/sm \u00b0C)<\/b> and it needs a <b>thermal power 30W\/m3<\/b>, then the needed power is exactly<\/p>\n<p class=\"p1\">30 (W\/m3) x 20 (sm) x 2.7 (m) = 1620 W<\/p>\n<p class=\"p1\">If we consider the system continuosly switched on <b>(it never happens with a chrono thermostat installed)<\/b>, the radiant panel un 5 hours absorbs<\/p>\n<p class=\"p1\">1620 (W) x 5 (h) = 8100 Wh = 8,1 kWh<\/p>\n<p class=\"p1\">If we hypothesize to pay energy 0,22 \u20ac\/kWh, we can reckon the cost per day:<\/p>\n<p class=\"p1\">8,1 (kWh) x 0,22 (\u20ac\/kWh) = 1,72 \u20ac\/day<\/p>\n<p class=\"p1\">2) We need to heat the same room ( 20 sm, 2,7 m height) with a sufficient insulation ( approximately 0,5 W\/sm \u00b0C). In this case the needed power per m3 is 22 W\/m3, then the total power will be:<\/p>\n<p class=\"p1\">22 (W\/m3) x 20 (sm) x 2.7 (m) = 1188 W<\/p>\n<p class=\"p1\">If we consider the system continuosly switched on <b>(it never happens with a chrono thermostat installed)<\/b>, the radiant panel un 5 hours absorbs<\/p>\n<p class=\"p1\">1188 (W) x 5 (h) = 5940 Wh = 5,94 kWh<\/p>\n<p class=\"p1\">If we hypothesize to pay energy 0,22 \u20ac\/kWh, we can reckon the cost per day:<\/p>\n<p class=\"p1\">5,94 (kWh) x 0,22 (\u20ac\/kWh) = 1,23 \u20ac\/day<\/p>\n<p class=\"p1\">3) If we try to heat the same room ( 20sm, 2.7 m height) in a passive house, with an excellent insulation (approximately 0,12 W\/sm \u00b0C), the needed power is 5W\/m3.<\/p>\n<p class=\"p1\">Then the total power will be:<\/p>\n<p class=\"p1\">5 (W\/m3) x 20 (sm) x 2,7 (m) = 270 W<\/p>\n<p class=\"p1\">If we consider the system continuosly switched on <b>(it never happens with a chrono thermostat installed)<\/b>, the radiant panel un 5 hours absorbs<\/p>\n<p class=\"p1\">270 (W) x 5 (h) = 1350 Wh = 1,35 kWh<\/p>\n<p class=\"p1\">If we hypothesize to pay energy 0,22 \u20ac\/kWh, we can reckon the cost per day:<\/p>\n<p class=\"p1\">1,3 (kWh) x 0,22 (\u20ac\/kWh) = 0,28 \u20ac\/day<\/p>\n<p class=\"p1\">Important: when we decide to install electric radiant panels with infrared rays emission, it\u2019s advised to lightly oversize the system. Indeed, due to the decreasing of the needed temperature by 1-3\u00b0C, we can obtain significant savings on energy consumption.<\/p>\n<p class=\"p1\">Obviously, if we can get energy from our <b>photovoltaic system, heating becomes a null cost system.<\/b><\/p>\n<p class=\"p1\">In facts radiant panels installation allows to heat <b>not the air of the environment, but the skin<\/b>, the objects, the walls, the floor. <b>With this system, we can feel the heating flow almost immediately.<\/b><\/p>\n<p class=\"p1\">This means that a radiant panel <b>can be lit where and when it\u2019s needed<\/b>. This way, the cost of <b>energy consumption becomes minimum, even for those who don\u2019t own a photovoltaic system.<\/b><\/p>\n<p class=\"p1\">Overall, installing <b>control units to manage electric absorbtions<\/b>, we can <b>decrease consumption<\/b>, and it is <b>not needed to change the power available for the builnding<\/b> (famous 3,3 kW, 6 kW, 10 kW or more, offered by energy suppliers)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The heating systems through radiant panels must be sized according to the features of the house and to geographical conditions, so as all heating systems. <\/p>\n<a class=\"readmore-button\" href=\"https:\/\/calorstone.com\/en\/calcolo-rendimenti-termici-calorstone\/\">Read More<\/a>","protected":false},"author":7,"featured_media":561,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[640,641,6],"tags":[],"class_list":["post-11580","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ab-cupidatat-philos-fr-en","category-o-irure-nostrud-non-fr-en","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/posts\/11580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/comments?post=11580"}],"version-history":[{"count":0,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/posts\/11580\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/media\/561"}],"wp:attachment":[{"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/media?parent=11580"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/categories?post=11580"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/calorstone.com\/en\/wp-json\/wp\/v2\/tags?post=11580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}